Whale Tiptoe pump
Mk4 GP1309 |
| Also Service Kits/Assemblies: AK1304, AS1305, AS130 6 |
|
|
| Read carefully before
installation and use . |
To the Fitter:
Check that the product is suitable fo rthe intended application, follow installation instructions and ensure operating instructions are passed onto the end user .
To the User:
Read the following instructions carefully . Application:
This product is designed for use as a fresh water foot pump in caravans and boats. Use for any other purpose or with any other liquid, is not recommended and is entirely at the user's risk.
 |
Installation
Choose an installation where the pump can be operated comfortably.
- Cut a 3" (75 mm) diameter hole in the floor.
- Floor thickness: minimum 3 / 8 " (10 mm), maximum 2"(50 mm).
- One piece assembly fits directly onto floor.
- Secure with 3 screws .

Operation:
- Release plunger plate by twisting anti-clockwise.
- Pump up and down with your foot; vigorously for full flow, gently for controlled flow.
- When pumping is finished, push the plunger fully down, twist clockwise to lock
The Whale Tiptoe can be
used as a manual back-up
with an electric pump
provided that:
1. It is not a pressurized system. 2. It is placed between the in-line electric pump and the water supply. |
Maintenance:
Regular inspection of valves and seals is recommended with cleaning and replacement of components as necessary . Replacement parts are available in service kits and assemblies from dealers or direct from the manufacturer .
Note: For winter storage , ensure that the pump is drained completely to avoid frost damage. Helpful hints:
) The pump can be serviced using Service Kit AK1304 which contains the complete set of washers for the Mk3 and Mk4 pump.
b) If the pump is slow to prime, the cup washer may be worn or the valves are not seating properly. Check and replace these if neccessary using Service Kit AK1304.
c) If the pump will not pump: -check that the suction line is in the water.
- check that the hose connections are secure and that there are no air leaks.
- Check the washers in the pump, they may need to be replaced.
- if the outlet is an on/off faucet or tap, make sure that it is open to allow water to flow.
d) If the pump is leaking, it is likely that the gland washer is worn. A replacement for this part is contained in Service Kit AK1304. |
|
 |
| Should you wish to find out about other Whale Water System products please use the contact details below; |
Munster Simms Engineering Ltd .
Old Belfast Road,
Bangor, Co Down,
N.Ireland
BT19 1LT
Tel: +44 (0)28 9127 0531
Fax: +44 (0)28 9146 642 1
Web: http://www.whalepumps.com
Email: info@whalepumps.com
Ref No: 180.05 V10/97 |
|
The advice and tips on Thomson T-Line History & Information are free to copy for personal use, if you are a webmaster or company who wishes to use these sheets for your business or website please ask permission from the webmaster.
Thomson T-Line History & Information shall not be liable for any damage or difficulty, direct or indirect, arising from utilisation of the information contained within these pages. |
|
| |
|
| |
|
| |
Copyright © 1998 - 2008 Thomson T-Line History & Information |
|
| |
Disclaimer - The information provided on this Website site is offered with no warranty as to the authenticity, suitability or competence of the individual, company or service quoted here in. The Website shall not be liable for any damage or difficulty, direct or indirect, arising from utilisation of the information contained within these pages. Thomson T-Line History & Information is not responsible for the content of external websites. |
|
| |